HOME | ȸ¿ø°¡ÀÔ | ·Î±×ÀÎ | Áñ°Üã±â  








 
¤ý µðÁöÅÐ ÈÞ´ë¿ë dz¼Ó°è(TPI 555,SU.. [2016-01-12]
¤ý µðÁöÅÐ ÈÞ´ë¿ë dz¼Ó°è(TPI 565,SU.. [2016-01-12]
¤ý Áø°ø °ÔÀÌÁö(TPI 605 ¼³¸í¼­) [2016-01-12]
¤ý ȸÀü ÃøÁ¤±â(Á¢ÃË,ºñÁ¢ÃË °â¿ë)TPI 5.. [2016-01-12]
¤ý Â÷¾ÐÃøÁ¤ µðÁöÅÐ ¾Ð·Â°è(SD20 ¼³¸í¼­) [2016-01-12]
¤ý µðÁöÅÐ ¾Ð·Â°è(SS20 ¼³¸í¼­) [2016-01-12]


  »óÇ°¼Ò°³ < »óÇ°¼Ò°³  
Eppendorf Á¦Ç° > Spectro photometer
Biophotometer plus 6132

ºÐ·ù : Spectro photometer
ÆǸŰ¡°Ý :
¹è¼Ûºñ :   3500
Á¦Á¶»ç :   eppendorf
¼ö·® :  

Ư¡

Application

  • ÇÙ»ê Á¤·® (dsDNA, ssDNA, RNA, Oligo)
  • ´Ü¹éÁú Á¤·® (280 nm, Bradford, Lowry, BCA)
  • Cell density ÃøÁ¤(OD600)
  • Çü±¤ ½Ã¾à°ú °áÇÕÀ² ¹ÝÀÀ ÃøÁ¤ (dye 550/650, e.g., Cy-3, Cy-5)
  • È¿¼ÒÈ­ ¹ÝÀÀ: endpoint ÃøÁ¤ (¿¹., ¼¼Æ÷ »ý¹°ÇÐÀû assayÀÇ È¿¼ÒÈ­ ¹ÝÀÀ)
  • º°µµ °è»ê ¾øÀÌ ´ÜÀÏ ÆÄÀå´ëÀÇ Á÷Á¢ Èí±¤µµ ÃøÁ¤ : (230 nm, 260 nm, 280 nm, 340 nm, 405 nm, 490 nm, 550 nm, 595 nm, 650 nm)

    Á¦Ç° Ư¡
  • 9 °¡Áö ÆÄÀå´ë ¹× 32°³ ³»Àå ÇÁ·Î±×·¡¹Ö¹ýÀ¸·Î ´Ù¾çÇÑ ÀÀ¿ë¿¡ ½±°Ô Àû¿ë °¡´É
  • 9 °¡Áö ÆÄÀåÀº ºÐÀÚ»ý¹°ÇÐ ½ÇÇè, »ýÈ­ÇнÇÇè, ¼¼Æ÷ »ý¹°ÇÐÀû ½ÇÇèÀ» ÇÏ´Â ´ëºÎºÐÀÇ ½ÇÇè½ÇÀÇ ÀϹÝÀûÀÎ ½ÇÇè ¿ëµµ¿¡ ÀûÇÕ
  • ¹Ì¸® ³»ÀåµÈ ½ÇÇè¹ýÀ¸·Î ÇÙ»ê ¹× ´Ü¹éÁú Á¤·® »Ó¸¸ ¾Æ´Ï¶ó Çü±¤ ½Ã¾à°ú °áÇÕ ¹ÝÀÀ ÃøÁ¤¿¡µµ »ç¿ë °¡´É
  • Èñ¼® ¹èÀ²À» ÀÚµ¿À¸·Î °è»êÇØÁÖ¾î º°µµ °è»ê°úÁ¤ ¾ø¾î ½ÇÇè½Ã°£ Àý°¨ ¹× °£ÆíÇÑ ½ÇÇèÀÌ °¡´É
  • 340 nm, 405 nm, 490 nm µî °¡Àå ÀϹÝÀûÀÎ ÆÄÀå´ë¿¡¼­ÀÇ Assay ½ÇÇèÀÌ °¡´É
  • ´ÜÀÏ ÆÄÀå¿¡¼­ º°µµ °è»ê ¾øÀÌ ÃøÁ¤
  • ÃøÁ¤µÈ µ¥ÀÌÅÍ´Â 100°³±îÁö ÀÚµ¿ ÀúÀå ±â´É
  • ½ÇÇè½Ã ¿¡·¯ ¾ø´Â ÀÛµ¿ÀÌ °¡´ÉÇÑ ÀÎü°øÇÐÀûÀÌ°í ½ÉÇÃÇÑ ÇÁ·Î±×·¡¹Ö Å°
  • ½¬¿î ÀÛµ¿À» À§ÇØ ±â´ÉÅ°°¡ »ö±ò·Î ±¸ºÐµÇ¾î ÀÖÀ½
  • A4¿ëÁö Á¤µµÀÇ ÄÄÆÑÆ®ÇÑ µðÀÚÀÎÀ¸·Î ÀÚ¸®¸¦ Àû°Ô Â÷ÁöÇϸç À̵¿ÀÌ °£ÆíÇÏ´Ù.
  • PC ¾øÀÌ »ç¿ë °¡´É
  • Á¦³í Ç÷¡½Ã ·¥ÇÁ¸¦ »ç¿ëÇÏ¿© ¿ö¹Ö¾÷ ½Ã°£ÀÌ ÇÊ¿ä ¾øÀÌ ¹Ù·Î »ç¿ë°¡´É : ½ÇÇè ½Ã°£ Àý¾à
  • Á¦³í Ç÷¡½Ã ·¥ÇÁ »ç¿ëÀ¸·Î ¹Ý¿µ±¸ÀûÀÎ ¼ö¸í

    Technical lnformation

    Optical system:

    Absorption singlebeam photometer with reference beam

    Light source: Xenon flash lamp
    Light beam height: 8.5 mm
    Measuring wavelengths: 230, 260, 280, 340, 405, 490, 550, 595, 650 nm
    Spectral bandwidth:

    5 nm at 230?40 nm, 7 nm at 405?50 nm

    Wavelength systematic error:

    ¡¾ 1nm at 230 ~ 280 nm, ¡¾2nm at 340 ~ 650 nm

    Photometric measuring range:

    0 to 3 A (2 A at 340 nm); Dye Methods: 2 A at 550 nm/650 nm

    Photometric random error: ¡¾0.002 A at 0 A; ¡¾0.005 A at 1 A
    Photometric systematic error:

    ¡¾1% at 1 A

    Method dependent calculation: - Absorbance
    - Concentration via factor
    - Concentration via calibration with 1 to 10 standards
    - One point calibration (1 standard)
    - Linear regression (2 to 10 standards)
    - Nonlinear regression (3rd degree polynom; 4 or 5 to 10 standards),
    1 x, 2 x or 3 x determination
    - Ratio 260/280, ratio 260/230, molar concentration, total yield
    - For dye methods: FOI (frequency of incorporation)
    Calibration memory:

    For all calibration procedures

    Results memory: For 100 results with absorbance and ratio values, sample number, sample dilution, date and time
    Interface: RS232C, serial, PC connection optional
    Power requirement: Approx. 20 W in operation, approx. 10 W in Standby mode
    Power supply: 100~240 V, ¡¾10%; 50~60 Hz, ¡¾5%
    Dimensions (W x D x H): 20 x 32 x 10 cm
    Weight: 3 kg
    Accessories:

    Thermal printer DPU 414, 40 characters/line; Secondary UVVIS filter set for verifying photometric and wavelength accuracy (NIST traceable)

    Cuvettes: UVette, Hellma TrayCell*, and common rectangular cuvettes of suitable glass or plastic materials

    Ordering Information

    Description Order no.
    BioPhotometer plus, 230 V/50?0 Hz 6132 000.008
    Secondary UV-VIS filter test set for verifying
    photometric precision and wavelength accuracy
    (NIST traceable)
    6131 928.007
    Thermal printer DPU 414, incl. power supply 230 V
    and printer cable
    6131 011.006
    Thermal paper (5 rolls) 0013 021.566
    UVette individually packaged single cuvettes,
    certified RNase, DNA and proteinfree, 80 pcs.
    0030 106.300
    UVette routine pack, Eppendorf Quality purity level,
    reclosable box, 200 pcs.
    0030 106.318
    Biophotometer Data Transfer Software 6132 845.007

  • ´çÀÏ ¿ÀÈÄ 1½Ã ÀÌÀü¿¡ ÁÖ¹® ¹× ÀÔ±Ý ¿Ï·á½Ã Àç°í¿¡ ÇÑÇÏ¿© ´çÀÏ Ãâ°íÇÕ´Ï´Ù.
    Ưº° Á¦ÀÛÇ°Àº Á¦À۱ⰣÀÌ ¼Ò¿äµË´Ï´Ù. 2~5ÀÏ (Åä¿äÀÏ,°øÈÞÀÏÀº Á¦¿Ü, µµ¼­Áö¿ª ¹× »ç¼­ÇÔ ÁÖ¼Ò´Â 4 ~ 6ÀÏ)
    ÁÖ¹®ÇϽŠ»óÇ°¿¡ µû¶ó ¹è¼Û±â°£ÀÌ Á¶±Ý »óÀÌÇÒ ¼ö ÀÖ½À´Ï´Ù.
    ÁÖ¹®ÇÏ½Ç ¶§ Èñ¸Á ¹è¼ÛÀÏÀÚ¸¦ ³Ë³ËÈ÷ Àâ¾ÆÁֽøé(3ÀÏÀÌ»ó) ¿øÇϽô ³¯Â¥¿¡ ¹è¼ÛÇÒ ¼ö ÀÖµµ·Ï ÃÖ¼±À» ´ÙÇÏ°Ú½À´Ï´Ù.
    ºÒ°¡Ç×·ÂÀû(ÀϽÃÇ°Àý, Á¦Á¶»ç »óÇ°¼ö±Þ ¹®Á¦, ¼öÀÔÁ¦Ç° µî)ÀÎ »çÀ¯·Î ¹è¼ÛÀÌ ´Ù¼Ò ´Ê¾îÁú¼ö ÀÖ½À´Ï´Ù.
    ¹è¼ÛÀÌ ´Ê¾îÁö´Â °æ¿ì °í°´´Ô²² ¸ÞÀÏÀ̳ª ÀüÈ­·Î Á÷Á¢ ¿¬¶ôÀ» µå¸®°Ú½À´Ï´Ù
    *** ±³È¯ ¹× ¹ÝÇ°ÀÌ °¡´ÉÇÑ °æ¿ì ***
    »óÇ°À» °ø±Þ ¹ÞÀ¸½Å ³¯·ÎºÎÅÍ 5ÀÏ À̳»
    ´Ü, »óÇ°À» °³ºÀÇÏ¿© »óÇ°°¡Ä¡°¡ »ó½ÇµÈ °æ¿ì¿¡´Â ±³È¯/¹ÝÇ°ÀÌ ºÒ°¡´ÉÇÕ´Ï´Ù.
    °ø±Þ¹ÞÀ¸½Å »óÇ° ¹× ¿ë¿ªÀÇ ³»¿ëÀÌ Ç¥½Ã.±¤°í ³»¿ë°ú ´Ù¸£°Å³ª ´Ù¸£°Ô ÀÌÇàµÈ °æ¿ì

    *** ±³È¯ ¹× ¹ÝÇ°ÀÌ ºÒ°¡´ÉÇÑ °æ¿ì ***
    ÇÏÀÚ°¡ ¾ø´Â »óÇ°À» Åùè»ç·ÎºÎÅÍ Àεµ ¹ÞÀ¸½Å ³¯·ÎºÎÅÍ 7ÀÏÀÌÈÄ.
    °í°´´ÔÀÇ Ã¥ÀÓ ÀÖ´Â »çÀ¯·Î »óÇ°µîÀÌ ¸ê½Ç ¶Ç´Â ÈÑ¼ÕµÈ °æ¿ì.
    ´Ü »óÇ°ÀÇ ³»¿ëÀ» È®ÀÎÇϱâ À§ÇÏ¿© Æ÷Àå µîÀ» ÈѼÕÇÑ °æ¿ì´Â Á¦¿Ü
    Æ÷ÀåÀ» °³ºÀÇÏ¿´°Å³ª Æ÷ÀåÀÌ ÈÑ¼ÕµÇ¾î »óÇ°°¡Ä¡°¡ »ó½ÇµÈ °æ¿ì
    °í°´´ÔÀÇ »ç¿ë ¶Ç´Â ÀϺΠ¼Òºñ¿¡ ÀÇÇÏ¿© »óÇ°ÀÇ °¡Ä¡°¡ ÇöÀúÈ÷ °¨¼ÒÇÑ °æ¿ì
    ½Ã°£ÀÇ °æ°ú¿¡ ÀÇÇÏ¿© ÀçÆǸŰ¡ °ï¶õÇÒ Á¤µµ·Î »óÇ°µîÀÇ °¡Ä¡°¡ ÇöÀúÈ÷ °¨¼ÒÇÑ °æ¿ì
    ƯÈ÷ ³ÃÀå,³Ãµ¿ Á¦Ç° ¹× º°µµÀÇ ¼öÀÔ ÁÖ¹®¿¡ ÀÇÇÑ »óÇ°Àº ¹ÝÇ°ºÒ°¡ ÇÕ´Ï´Ù

    (ÀÚ¼¼ÇÑ ³»¿ëÀº °í°´¸¸Á·¼¾ÅÍ e-mail »ó´ãÀ» ÀÌ¿ëÇØ Áֽñ⠹ٶø´Ï´Ù.)


    °í°´´ÔÀÇ ¸¶À½ÀÌ ¹Ù²î¾î(°í°´º¯½É) ±³È¯, ¹ÝÇ°À» ÇÏ½Ç °æ¿ì »óÇ°¹Ý¼Û ºñ¿ëÀº °í°´´Ô²²¼­ ºÎ´ãÇÏ¼Å¾ß ÇÕ´Ï´Ù.(»ö»ó ±³È¯, »çÀÌÁî ±³È¯ µî Æ÷ÇÔ)

    A/S´Â Á¦Ç°¿¡ µû¶ó Â÷ÀÌ°¡ ÀÖ½À´Ï´Ù. Á¦Ç°ÀÇ »ç¿ëÀü ¹ß°ßÇÑ ÇÏÀÚ¿¡ ´ëÇؼ­´Â ±³È¯À» ¿øÄ¢À¸·Î ÇÏ°í ÀÖÀ¸¸ç »ç¿ëÁß ¹ß»ýµÈ A/SºÎºÐÀº Á¦Ç°¿¡ µû¶ó Â÷ÀÌ°¡ ÀÖÀ½À¸·Î ÀüÈ­³ª ¸ÞÀÏ·Î ¹®ÀÇÇØ Áֽøé Á¦Ç°È®ÀÎÈÄ ´äº¯µå¸®µµ·Ï ÇÏ°Ú½À´Ï´Ù.

    ¹Ì¼¼ÇÑ »ö»óÂ÷ÀÌ´Â ÇÏÀÚ°¡ ¾Æ´Ï¸ç, ¸ð´ÏÅ͸¶´Ù °¢°¢ÀÇ »ö»óÂ÷ÀÌ°¡ ÀÖÀ» ¼ö ÀÖ½À´Ï´Ù.

    »óÇ°Æò µ¡±ÛÀÌ ¾ø½À´Ï´Ù.
    ÀÛ¼ºÀÚ : ºñ¹Ð¹øÈ£ : ÀÔ·ÂÇÏÁö ¾ÊÀ¸½Ã¸é ·Î±×ÀÎ Æнº¿öµå·Î ÀԷµ˴ϴÙ. »óÇ°Æò µ¡±Û¾²±â
    ³»¿ë